Grade 3 alarm enclosure SATEL OMI-4 metal enclosure with 75 VA AC transformer for 17 Ah battery
- Metal enclosure for INTEGRA PLus control panels, for EN50131 Grade 3 intrusion alarm systems, with AC/AC 75 VA transformer and space for 17 Ah battery.
Subscription products in your shopping cart
Set one delivery frequency for all subscription products in your cart every:
Subscription products in your shopping cart
OMI-4 - metal enclosure with 75 VA transformer for INTEGRA PLus (EN50131 Grade 3) control panels
The OMI-4 enclosure is designed for the implementation of intrusion alarm systems complying with EN50131 Grade 3 requirements using INTEGRA PLus control panels. It is equipped with a reinforced AC/AC 75 VA transformer and a double tamper protection mechanism.
- Designed for EN50131 Grade 3 compliant systems
- Compatible with INTEGRA PLus control panels
- Double tamper protection (opening and detachment from ground)
- Built-in amplified AC/AC 75 VA transformer
- Space for a 17 Ah battery
Purpose and application of the OMI-4 enclosure
The OMI-4 enclosure has been designed for the construction of wired intrusion alarm systems with increased security, meeting the requirements of Grade 3 of the EN50131 standard. Thanks to its compatibility with INTEGRA PLcontrol panels, it enables the implementation of extensive alarm installations in facilities requiring a high level of security, such as commercial, office or industrial facilities.
The housing's design provides space for mounting the control panel's main board, expansion modules and a 17 Ah battery, which allows you to build a compLetaneous system power and control set in a single, enclosed metal housing. The use of metal construction also facilitates proper wiring and mounting of accessories inside the enclosure.
Security and power supply
The OMI-4 is equipped with a tamper detection mechanism, including control of opening the enclosure cover and detaching it from the ground, which allows the control panel to immediately detect attempts to tamper with the system. Dual tamper protection supports compliance with EN50131 requirements for Grade 3.
The enclosure uses a 75 VA amplified AC/AC transformer, supplied with 230 V AC (±15%), 50-60 Hz, providing an output voltage of 20 V AC, 50 Hz. Such a selection of parameters allows stable power supply to the control panel and cooperating expansion modules, while maintaining an adequate power reserve for the system.
Technical data
| Parameter | Value |
|---|---|
| Application | Intrusion alarm systems compliant with EN50131 Grade 3 |
| Intended use of control panels | INTEGRA PLus |
| Anti-tampering protection | Double: detection of opening the housing and detachment from the ground |
| Transformer | AC/AC, 75 VA |
| Power supply voltage (input) | 230 V AC (±15%), 50-60 Hz |
| Transformer output voltage | 20 V AC, 50 Hz |
| Battery space | 17 Ah battery |
| Housing dimensions | 330 × 405 × 110 mm |
| Safety class in accordance with EN50131 | Grade 3 |
Source of technical data:data sheet for model OMI-4 Link
FAQ - Frequently asked questions
What kind of alarm systems is the OMI-4 enclosure designed for?
OMI-4 is designed for the implementation of intrusion alarm systems compliant with EN50131 Grade 3 requirements, using INTEGRA PLus control panels.
Does the OMI-4 enclosure work with INTEGRA PLus control panels?
Yes, the OMI-4 enclosure is dedicated for mounting INTEGRA PLus control panels and related expansion modules.
What kind of tamper protection does the enclosure have?
The enclosure has a mechanism to detect the opening of the cover and detachment from the ground, which is a double tamper protection.
What class according to EN50131 is the OMI-4 enclosure?
OMI-4 meets the requirements of EN50131 for Grade 3.
What are the dimensions of the OMI-4 enclosure?
The dimensions of the enclosure are 330 × 405 × 110 mm.
What kind of transformer is used in the enclosure?
An amplified AC/AC transformer of 75 VA is used in the enclosure.
What supply voltage is required for the transformer in the OMI-4?
The transformer is supplied with 230 V AC (±15%), 50-60 Hz.
What output voltage does the chassis transformer provide?
The transformer provides an output voltage of 20 V AC, 50 Hz.
Can a battery be mounted in the enclosure?
Yes, the enclosure provides space for mounting a 17 Ah battery.
Does the OMI-4 provide space for expansion modules?
Yes, the design of the housing provides space for the control panel motherboard and expansion modules.
Is the enclosure made of metal?
OMI-4 is a metal enclosure designed for use in alarm systems.
Do the parameters of the enclosure allow use in facilities with higher security requirements?
Yes, meeting EN50131 Grade 3 requirements and double tamper protection allow the enclosure to be used in facilities with high security requirements.
Does the 50-60 Hz power frequency apply to the transformer input?
Yes, the supply voltage of 230 V AC (±15%) applies to the frequency of 50-60 Hz at the input of the transformer.
What is the frequency of the output voltage of the transformer?
The output voltage of the transformer is 20 V AC, 50 Hz.
Does the enclosure itself function as a control panel?
No, the OMI-4 is an enclosure with a transformer for mounting the control panel and modules, not a stand-alone control panel.
Is the information about the appearance of the enclosure binding?
The manufacturer stipulates that the actual appearance of the products may differ from that shown in the illustrative materials.
Are the product descriptions legally binding?
The manufacturer specifies that the posted product descriptions are for informational purposes only.
The OMI-4 enclosure is an element of the burglary and panic alarm system designed to cooperate with INTEGRA PLus control panels, while meeting the requirements of EN50131 Grade 3. Thanks to the built-in 75 VA transformer and space for a 17 Ah battery, it enables the realization of a stable power supply and the installation of key system components in a single metal enclosure.