Input-Output Expansion Module SATEL INT-PP board 8 wired inputs 8 12 V DC outputs
- INT-PP module for INTEGRA/INTEGRA PLus/ACCO-NT control panels, is used to expand the system with 8 hardwired inputs and 8 programmable outputs; supply voltage 12 V DC (±15%).
Subscription products in your shopping cart
Set one delivery frequency for all subscription products in your cart every:
Subscription products in your shopping cart
INT-PP - input and output expander for INTEGRA / INTEGRA PLus / ACCO-NT control panels
INT-PP is an expansion module designed for cooperation with INTEGRA and INTEGRA PLus family alarm control panels and ACCO-NT access control panel. The device allows you to expand the system with 8 additional wired inputs and 8 programmable OC and relay type outputs.
- Cooperation with INTEGRA, INTEGRA PLus and ACCO-NT control panels
- System expansion with 8 wired inputs
- 4 OC type outputs and 4 relay outputs
- Support for NO, NC, EOL, 2EOL/NO, 2EOL/NC, 3EOL configurations
- Possibility to connect to RS-485 bus with software upgrade
INT-PP module purpose and application
The INT-PP module is designed to expand the INTEGRA and INTEGRA PLus alarm control panels and the ACCO-NT access control panel with additional inputs and outputs. This makes it possible to connect a greater number of detectors, actuators and building automation elements in a single system. INT-PP replaces the earlier CA-64 PP module, ensuring compatibility with modern control panel features and security standards.
The device provides 8 hard-wired inputs with various parameterization options, allowing flexible adaptation to the detectors used and the wiring method. An additional tamper input facilitates detection of unauthorized opening of the enclosure in which the module is mounted, increasing the security level of the installation.
Features, input and output handling and system integration
INT-PP expands the system with 8 programmable outputs: 4 OC-type outputs and 4 relay outputs that can control sirens, relays, automation elements or other external devices. These outputs have a certain current and voltage carrying capacity, allowing safe cooperation with devices in the installation. The additional +12V output available on the module has a high current carrying capacity and can supply power to connected system components.
The INT-PP module's inputs support NO, NC, EOL, 2EOL/NO, 2EOL/NC (for alarm panels) and 3EOL configurations (for INTEGRA PLus control panels), allowing you to connect roller shutter and vibration detectors in a way that ensures proper differentiation of states. The module can be connected to the RS-485 bus, through which software updates are possible. INT-PP meets the requirements of environmental class II according to EN 50130-5 and Grade 3 (without power supply) or Grade 2 (with APS-412 power supply) according to EN 50131, which makes it applicable to systems with higher security requirements.
Technical specifications
| Parameter | Value |
|---|---|
| Purpose | Expansion of INTEGRA, INTEGRA PLus and ACCO-NT control panels with additional inputs and outputs |
| Number of wired zones | 8 |
| Number of total outputs | 8 programmable |
| OC type outputs | 4 |
| Relay outputs | 4 |
| Supported input configurations | NO, NC, EOL, 2EOL/NO, 2EOL/NC (control panels only), 3EOL (INTEGRA PLus only) |
| Operation of detectors | Roller shutter and vibration detectors (control panels only) |
| Tamper input | Yes, for detecting opening of module housing |
| Communication interface | RS-485 bus (software can be updated via it) |
| Power supply voltage (±15%) | 12 V DC |
| Current consumption in standby state | 35 mA |
| Maximum current consumption | 150 mA |
| OC type outputs load capacity | 50 mA / 12 V DC |
| Load capacity of relay outputs (resistive load) | 1 A / 30 V DC |
| Current-carrying capacity of +12 V output | 2.5 A / 12 V DC |
| Operating temperature range | -10 °C...+55 °C |
| Maximum humidity | 93 ± 3% |
| Dimensions | 140 x 68 mm |
| Weight | 80 g |
| Environmental class as per EN 50130-5 | II |
| Grade of protection according to EN 50131 (without power supply) | Grade 3 |
| Grade of protection according to EN 50131 (with APS-412 power supply) | Grade 2 |
Source of technical data:data sheet of INT-PP model Link
FAQ - frequently asked questions
1. To which control panels can the INT-PP module be connected?
The INT-PP module is designed to cooperate with the INTEGRA and INTEGRA PLus families of alarm control panels, as well as with the ACCO-NT access control panel.
2. How many additional zones does the INT-PP make available?
INT-PP provides 8 additional wired inputs.
3. How many outputs does the INT-PP module have and what type are they?
The module has 8 programmable outputs, including 4 OC type outputs and 4 relay outputs.
4. What input configurations are supported by the INT-PP?
INT-PP supports NO, NC, EOL, 2EOL/NO, 2EOL/NC (for alarm panels) and 3EOL (for INTEGRA PLus panels) configurations.
5. Does the INT-PP module support roller shutter and vibration detectors?
Yes, the module supports roller shutter and vibration detectors in systems with alarm control panels.
6. Does the INT-PP have a tamper input?
Yes, the INT-PP has an additional tamper input to detect unauthorized opening of the module housing.
7. What power supply voltage is required for the INT-PP?
The required power supply voltage for the INT-PP module is 12 V DC with a tolerance of ±15%.
8. What is the standby current consumption of the module?
The standby current consumption is 35 mA.
9. What is the maximum current consumption of the INT-PP?
The maximum current consumption of the INT-PP module is 150 mA.
10. What is the load capacity of the OC type outputs?
The OC type outputs have a load capacity of 50 mA at 12 V DC.
11. What is the load capacity of the relay outputs?
Relay outputs have a load capacity of 1 A at 30 V DC for a resistive load.
12. What load can supply the +12 V output of the module?
The +12 V output of the INT-PP module can supply a load of up to 2.5 A at 12 V DC.
13. In what temperature range can the INT-PP operate?
The operating temperature range of the INT-PP module is -10 °C to +55 °C.
14. What is the permissible operating humidity of the module?
The allowable maximum operating humidity is 93% ± 3%.
15. What are the dimensions of the INT-PP module?
The dimensions of the module are 140 x 68 mm.
16. What is the weight of the INT-PP module?
The weight of the INT-PP module is 80 g.
17. What environmental class does the INT-PP meet?
The module has an environmental class II according to EN 50130-5.
18. What degree of protection according to EN 50131 does the INT-PP meet?
The INT-PP meets Grade 3 (without power supply) and Grade 2 protection requirements in configuration with APS-412 power supply.
19. Is it possible to update the INT-PP module software?
Yes, updating the module's software is possible via the RS-485 bus.
20. Does the INT-PP replace the older SATEL module ?
Yes, the INT-PP replaces the CA-64 PP module, offering system expansion with 8 inputs and 8 outputs and interoperability with current SATEL control panels .
Summary
INT-PP is an expansion module for INTEGRA, INTEGRA PLus and ACCO-NT control panels, offering 8 additional wired inputs and 8 programmable OC and relay type outputs. The device meets the requirements of EN 50130-5 and EN 50131 standards, ensuring high functionality and appropriate security level of the alarm system.