Fronius Eco 27.0-3-S Wi-Fi three-phase inverter. Available in 25.0 kW and 27.0 kW power classes optimally meet the requirements of large installations. Thanks to its light weight and SnapINverter mounting system, this transformerless device can be easily and quickly installed both indoors and outdoors. With an IP 66 protection rating, this inverter sets new standards. The use of integrated chain fuse sockets on both poles and optional DC surge protection means there is no longer a need for chain collection boxes. INPUT DATA
Number of MPP trackers
1,0
Max. input current (I dc max )
47,7 A
Max. short-circuit current of the module field
71,6 A
DC input voltage range (U dc min - U dc max )
580 - 1000 V
Start voltage (U dc start )
650,0 V
Rated input voltage (U dc,r )
580,0 V
MPP voltage range (U mpp min - U mpp max )
580 - 850 V
Useful MPP voltage range
580 - 850 V
Number of DC connections
6,0
Max. photovoltaic generator power (P dc max )
37.8 kWpeak OUTPUT DATA
AC rated power (P ac,r )
27.0 kW
Max. output power (P ac max )
27.0 kVA
AC output current (I ac nom )
40,9 / 39,1 A
Mains connection (U ac,r )
3~ NPE 400/230, 3~ NPE 380/220 V
AC voltage range (U min - U max )
150 - 275 V
Frequency (f r )
50 / 60 Hz
Frequency range (f min - f max )
45 - 65 Hz
Coefficient of non-linear distortion < 2 %
Power factor (cos φ ac,r )
0 - 1 ind./cap. GENERAL DATA
Dimensions (height)
725.0 mm
Dimensions (width)
510,0 mm
Dimensions (depth)
225,0 mm
Weight
35,7 kg
Degree of protection
IP 66
Protection class
1,0
Overvoltage category (DC/AC) 1)
2 / 3
Power consumption at night < 1 W
Inverter design concept
Transformerless
Cooling
Adjustable ventilation
Mounting
Indoor and outdoor mounting
Ambient temperature range
-25°C - +60°C
Permissible air humidity
0 - 100 %
Max. altitude above sea level 2)
2.000 m
DC connection technology
Screw terminals 6x DC+ and 6x DC- 2.5-16 mm²
AC connection technology
5-pin AC screw terminals 2.5-16 mm²
Certifications and standards
ÖVE / ÖNORM E 8001-4-712, DIN V VDE 0126-1-1/A1, VDE AR N 4105, IEC 62109-1/-2, IEC 62116, IEC 61727,
AS 3100, AS 4777-2, AS 4777-3, CER 06-190, G59/3, UNE 206007-1, SI 4777, CEI 0-16, CEI 0-21 EFFICIENCY FACTOR
Max. efficiency factor (photovoltaic installation - mains)
98,3 %
European efficiency factor (ηEU)
98,0 %
η at 5% P ac,r 3)
95,9 / 93,1 %
η at 10% P ac,r 3)
96,8 / 95,7 %
η at 20% P ac,r 3)
97,7 / 97,1 %
η at 25% P ac,r 3)
98,1 / 97,3 %
η at 30% P ac,r 3)
98,1 / 97,4 %
η at 50% P ac,r 3)
98,3 / 97,5 %
η at 75% P ac,r 3)
98,2 / 97,6 %
η at 100% P ac,r 3)
98,1 / 97,5 %
MPP adjustment efficiency factor
> 99,9 % PROTECTION
DC insulation measurement
Yes
Overload behavior
Offset operating point, power limiter
DC disconnect
Yes
Integrated chain fuse socket
Yes
Protection against pole swapping
Yes CONNECTIONS
WLAN / Ethernet LAN
Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 inputs and 4 digital inputs/outputs
Connection to remote control receiver
USB (type A socket) 4)
Datalogging, inverter update via USB media
2x RS422 (RJ45 socket) 4)
Fronius Solar Net
Signaling output 4)
Energy management (potential-free relay output)
Datalogger and web server
Integrated
External input 4)
S0 counter connection / surge protection monitoring
RS485
Modbus RTU SunSpec or energy meter connectionDo you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.