- NH3 Eaton 144122 three-pole NH3 strip fuse disconnector for disconnection and protection of three-phase circuits, rated current 630 A, voltage up to 690 V AC, screw mounting.
Subscription products in your shopping cart
Set one delivery frequency for all subscription products in your cart every:
Subscription products in your shopping cart
NH3 3-pole fuse disconnector, knife fuse strip disconnector, 630 A, 690 V AC, screw mounting - Eaton Bussmann 144122
Eaton Bussmann's NH3 3-pole knife fuse disconnect switch, rated 630 A and up to 690 V AC, provides reliable disconnection and protection of power circuits in industrial and commercial installations. The slatted design suitable for NH3 knife fuses allows for secure installation and easy operation and maintenance.
- Rated current up to 630 A for intensively loaded power circuits.
- Voltage rating up to 690 V AC suitable for industrial and power distribution installations.
- 3-pole design for three-phase power system applications.
- Strip design suitable for NH3 type knife fuses.
- Bolt mounting for stable and secure attachment in switchboards.
- A solution that complies with the requirements of modern protection and disconnection systems.
Application and function
Eaton Bussmann 144122 NH3 3-pole fuse disconnector is designed for protection and disconnection of electrical circuits with high currents in low-voltage installations. It is used in main switchgear and sub-switchgear, in control systems, machine power supply systems and in energy distribution systems, where rapid disconnection of the circuit in case of overload or short circuit is required (through NH3 fuse links used). The device serves as both a protective element and a switching apparatus for manual disconnection of power supply for service or expLoatation purposes.
Construction and installation
The disconnector is made as a strip fuse disconnector for NH3 knife fuses, suitable for screw mounting in switchboards and control cabinets. The three-pole design allows simultaneous disconnection of all phases, which increases the safety of operation and expLoatation. The housing and components are selected for operation at high rated currents and to ensure adequate mechanical rigidity and reliability of connections. The arrangement of terminals allows convenient connection of power and consumer cables in accordance with the current parameters of the device.
Safety and reliability
Eaton Bussmann 144122 fuse disconnector works with NH3 knife fuses, which provide fast short-circuit current limitation and protection of apparatus and wires. With its three-phase design and adaptation to high voltage ratings up to 690 V AC, the device is suitable for applications in demanding industrial conditions. The disconnector is designed to provide secure guidance and clamping of fuse links, minimizing the risk of contact overheating and ensuring long-term, stable operation. The appropriate screw fastening system and robust design promote high reliability in expLoatation.
| Parameter | Value |
|---|---|
| Product type | NH blade fuse disconnector for knife fuses |
| Fuse type | NH3 (NH size 3 knife fuse) |
| Number of poles | 3 |
| Rated current | 630 A |
| Rated operating voltage AC | up to 690 V AC |
| Type of disconnector | Three-pole fuse disconnector |
| Design | NH3 strip fuse switch disconnector |
| Mounting | Mounting on screws |
| Application | Low-voltage installations, switchgearnice main and sub-switchgear, power and control systems |
| Function | Disconnection and protection of circuits using NH3 fuse links |
| Purpose | Power distribution systems, power circuits in industry and commercial facilities |
The Eaton Bussmann 144122 NH3 fuse disconnector is a robust solution for demanding circuits with high current ratings in three-phase installations. Thanks to its simple installation and cooperation with NH3 knife fuses, it is a reliable element of protection and disconnection in modern power systems.
FAQ (customer)
- Q: What type of fuses can I use with this switch disconnector?
A: This device is designed for NH3 knife-blade fuses (size 3 NH fuses). - Q: Is this product suitable for three-phase installations?
A: Yes, it is a 3-pole switch disconnector intended for use in three-phase low-voltage power systems. - Q: What is the maximum rated current of this switch disconnector?
A: The maximum rated current is 630 A, making it suitable for high-current power circuits. - Q: Can I mount this device in a standard distribution board?
A: It is designed for screw mounting and can be installed in suitable distribution boards or switchgear with appropriate space and mechanical support. - Q: What is the maximum operating voltage of this product?
A: The device is suitable for operating voltages up to 690 V AC. - Q: Does this product provide overload and short-circuit protection by itself?
A: Protection is provided when it is used together with appropriate NH3 fuses; the switch disconnector serves as the fuse carrier and isolating device.
FAQ (expert)
- Q: What NH fuse standard does the device compLy with?
A: It is intended for standard NH3 knife-blade fuses used in low-voltage power distribution systems; detailed standards and approvals are to be verified in the official Eaton Bussmann technical documentation. - Q: Is there any specific short-circuit rating (Icc) defined for this model?
A: The exact short-circuit withstand and breaking capacities depend on the fuse characteristics; precise values should be taken from the manufacturer’s datasheet and coordination tables. - Q: Can this switch disconnector be used as a main switch in industrial panels?
A: Yes, provided that its rated current, voltage, and insulation properties meet the system requirements and that it is appLied together with suitable NH3 fuses and appropriate upstream and downstream coordination. - Q: Are there any accessories such as terminal covers or phase barriers available for this series?
A: Possible accessories, including shrouds, phase barriers, or connection kits, should be checked in the Eaton Bussmann catalog for NH fuse switch disconnectors. - Q: Does the device support top or bottom cable entry, or busbar connections?
A: The mechanical design generally allows screw-type connections that may be used with cables or busbars; exact terminal configuration must be confirmed in the dimensional drawings and instructions. - Q: What are the creepage and clearance distances for 690 V appLications?
A: Detailed insulation distances and pollution degree suitability are specified in the product’s technical documentation and should be evaluated against the installation environment.
Reviews
- Reliable NH3 fuse switch disconnector that works well in heavy-duty industrial panels.
- Clear three-pole design and straightforward mounting make it easy to integrate into existing switchboards.
- Provides robust current handling at 630 A, suitable for demanding power distribution circuits.
- Mechanical construction feels solid, with stable screw mounting once installed.
- Works effectively with standard NH3 fuses, ensuring predictable protection performance.
- Good choice for modernizing older installations that require higher current ratings.
- SimpLe, functional device that fulfills the role of both fuse carrier and isolator.
- Integration into three-phase systems is uncompLicated, provided that panel space is properly pLanned.
- Once installed, maintenance and fuse repLacement are straightforward for trained personnel.
- A practical solution from a well-known brand for low-voltage power distribution appLications.