- Eaton NZMN3-VE400 3P 400A power circuit breaker for protection and connection of three-phase circuits in low-voltage installations; rated current 400 A.
Subscription products in your shopping cart
Set one delivery frequency for all subscription products in your cart every:
Subscription products in your shopping cart
259132 Eaton Moeller series FAZ miniature circuit breaker FAZ-C16/2-NA, 2-pole, C-characteristic, 16 A, 240/415 V AC, 10 kA
The Eaton Moeller series FAZ-C16/2-NA two-pole overcurrent circuit breaker provides reliable protection for conductors and circuits in low-voltage installations, in accordance with stringent IEC/EN 60898-1 and IEC/EN 60947-2 standards. The apparatus offers a C-characteristic trip characteristic, a high short-circuit capacity of 10 kA, and a wide range of applications in single-phase and three-phase circuits.
- Rated current of 16 A and characteristic C for protecting consumer circuits with medium-level inrush currents (motors, lighting, power supplies).
- Two-pole design with complete disconnection, suitable for disconnecting the phase and neutral conductors.
- Short-circuit capacity of 10 kA at 240/415 V AC in accordance with IEC/EN 60898-1 provides a high level of safety in installations.
- Capable of pLrimming, accepting side and front accessories (auxiliary contacts, triggers), and comb supply.
- Clear contact position indicator and can be mounted on a standard 35mm DIN rail.
- Compliance with IEC/EN 60898-1, IEC/EN 60947-2 standards and certifications meets the requirements of residential and commercial applications.
Purpose and application range
The Eaton Moeller series FAZ-C16/2-NA overcurrent circuit breaker is designed to protect conductors, lines and loads from the effects of overloads and short circuits in AC circuits. It is characterized by tripping characteristic C, which allows it to be used in circuits with moderate inrush currents, such as in general installations in residential and public buildings, lighting circuits, plug sockets and small drives. The apparatus can be used in single-phase and three-phase systems (in multi-pole configurations) with voltage ratings up to 240/415 V AC. Thanks to its compatibility with a wide range of accessories, the FAZ series facilitates functional expansion of switchgear, such as status signaling, remote triggering or mechanical interlocks.
Construction, installation and expLoatation
The FAZ-C16/2-NA is a two-module unit for mounting on a standard 35mm DIN rail, with screw terminals suitable for copper conductors of the appropriate cross-section. The integrated contact position indicator allows easy control of the on or off status, and the appropriately shaped switching lever facilitates manual operation. The design of the device allows the use of rail (comb) bridges to quickly supply a larger number of circuit breakers in the switchgear, which reduces installation time and minimizes the possibility of wiring errors. The apparatus is adapted for use with side-mounted or front-mounted auxiliary elements, such as auxiliary contacts, alarm contacts or rise and undervoltage triggers, which allows further integration with control and monitoring systems. The circuit breaker is designed to meet the requirements for touch safety and resistance to environmental factors encountered in typical apLications of buildings.
Safety, compliance and performance
The device meets the requirements of IEC/EN 60898-1 for overcurrent circuit breakers used in domestic installations and IEC/EN 60947-2 for power circuit breakers in industrial applications, which guarantees a high level of safety and operational reliability. The rated short-circuit capacity of the apparatus is 10 kA at 240/415 V AC, so it can be used in circuits with relatively high levels of short-circuit current, with appropriate selection conditions. Tripping characteristic C provides triggering in the range of 5-10 times the rated current in the short-circuit circuit, which allows tolerating typical inrush currents, while providing effective protection against short circuits. The device is designed to operate in standard climatic and temperature conditions specified in the manufacturer's documentation, with appropriate derating at elevated ambient temperatures. The insulation materials used and the design of the enclosure ensure arc resistance and safe dissipation of short-circuit energy, minimizing the risk of damage to the installation.
| Parameter | FAZ-C16/2-NA |
|---|---|
| Product series | Eaton Moeller series FAZ |
| Type of apparatus | Overcurrent circuit breaker (MCB), modular |
| Part number | 259132 |
| Commercial designation | FAZ-C16/2-NA |
| Number of poles | 2 |
| Tripping characteristic | C |
| Rated current In | 16 A |
| Rated operating voltage AC | 240/415 V AC |
| Rated frequency | 50/60 Hz |
| Rated short circuit capacity Icn (IEC/EN 60898-1) | 10 kA |
| Standards and norms | IEC/EN 60898-1, IEC/EN 60947-2 (see documentation for details) |
| Type of application | Protection of conductors and consumers against overload and short circuit in low-voltage installations |
| Typical applications | Residential, commercial, small industrial installations |
| Possibility of using accessories | Yes, FAZ series side and front accessories (auxiliary contacts, alarms, triggers, etc.) |
| Mounting | On a 35 mm DIN rail |
| Wiring method | Screw terminals (detailed wire cross sections according to the datasheet) |
| Possibility of comb power supply | Yes, designed to work with busbars (busbars) |
| Contact position indicator | Yes, visual ON/OFF indicator |
| Type of circuits | Single-phase and three-phase circuits (in multi-pole configurations in the system) |
| Operating environment | Standard indoor installation conditions; requirements according to FAZ series standards |
| Degree of protection of the enclosure | In accordance with the design of the standard MCB modular enclosure (see FAZ documentation for details) |
| Possibility of pLrimming | Yes (using suitable accessories) |
| Housing material | Insulating material with high liquid and mechanical resistancepLn (see technical documentation for details) |
The Eaton Moeller series FAZ-C16/2-NA double-pole overcurrent circuit breaker is a robust and flexible solution for circuit protection in modern electrical installations. The combination of C characteristics, 10 kA short-circuit capacity and compatibility with FAZ series accessories ensures a high level of safety and easy integration in residential and commercial switchgear.
FAQ (customer)
- Q: For what type of circuits can I use the FAZ-C16/2-NA breaker?
A: It is suitable for low-voltage AC circuits in residential, commercial and small industrial installations, typically for socket, lighting and small motor loads with moderate inrush currents. - Q: What does the “C” characteristic mean for this breaker?
A: The C-curve means the breaker trips magnetically at roughly 5–10 times its rated current, allowing for typical inrush currents while still providing short-circuit protection. - Q: Can this device switch off both phase and neutral conductors?
A: Yes, it is a 2-pole breaker designed to disconnect two conductors, commonly phase and neutral, depending on the wiring scheme. - Q: Is the breaker suitable for DIN rail mounting in a standard distribution board?
A: Yes, it is a modular device for 35 mm DIN rail mounting, compatible with standard distribution enclosures. - Q: Can I add auxiliary contacts or shunt trips to this breaker?
A: The FAZ series accepts side- and front-mount accessories such as auxiliary and alarm contacts or shunt and undervoltage releases. - Q: What short-circuit level can this breaker safely interrupt?
A: It has a rated short-circuit breaking capacity of 10 kA at 240/415 V AC in accordance with IEC/EN 60898-1.
FAQ (expert)
- Q: Under which standards is the FAZ-C16/2-NA certified?
A: It is designed and tested according to IEC/EN 60898-1 for household MCBs and IEC/EN 60947-2 for circuit-breakers for industrial appLications. - Q: What is the rated operational voltage and frequency range?
A: The breaker is intended for 240/415 V AC systems at 50/60 Hz, within the limits defined in the product documentation. - Q: How is selectivity and back-up protection handled with upstream devices?
A: Selectivity and back-up characteristics depend on the specific upstream protective device; coordination tables in Eaton documentation should be used for precise selection. - Q: Are busbar feeding solutions available for this device?
A: Yes, the FAZ series is compatible with Eaton comb busbars, enabling fast and standardized feeding of multipLe breakers. - Q: Can the breaker be sealed or locked in a given position?
A: PLombing and locking options are available via dedicated accessories to secure the operating handle or cover. - Q: What derating should be considered at higher ambient temperatures?
A: Thermal derating curves are provided in the technical datasheet; current-carrying capacity decreases with increased ambient temperature and must be considered in design.
Reviews
- Reliable breaker, works flawlessly in a small commercial distribution board with mixed lighting and socket circuits.
- Good integration with Eaton busbars made installation very quick and tidy.
- Used several FAZ-C16/2 units in a renovation project; no nuisance tripping and solid build quality.
- Clear contact position indicator and firm handle movement give confidence during operation.
- Compatible accessories like auxiliary contacts made it easy to link the breaker to a monitoring system.
- Performs well in environments with frequent switching operations without noticeable wear.
- Good balance between price and performance, especially considering the 10 kA breaking capacity.
- Robust housing and terminal design make wiring secure, even with repeated changes during commissioning.
- Used as protection for small motor loads; the C characteristic handles inrush currents as expected.
- Standard DIN rail mounting and compact modular width fit easily into existing panels.