- Eaton 184762 PKZM0-16 motor circuit breaker, 3-pole. Used for manual switching on and off of a motor and overload and short-circuit protection. Current setting range 11-16 A, DIN rail mounting.
Subscription products in your shopping cart
Set one delivery frequency for all subscription products in your cart every:
Subscription products in your shopping cart
Eaton 184762 - PKZM0-16 motor circuit breaker, 11-16 A, 3-pole
Eaton's PKZM0-16 motor circuit breaker (cat. no. 184762) is a compact device for reliable motor protection in the 11-16 A current range. It provides effective short-circuit and overload protection and the ability to manually switch the drive on and off.
- Current setting range of 11-16 A, suitable for typical three-phase motors.
- 3-pole design for three-phase grid applications.
- Short-circuit breaker with high breaking capacity for installation protection.
- Manual operation via a knob on the front of the apparatus.
- Compact housing suitable for DIN rail mounting.
- Compatible with Eaton PKZ/PKZM0 modular apparatus system.
Application and protective functions
The Eaton PKZM0-16 motor circuit breaker (184762) is designed for direct protection of three-phase motors against the effects of overloads, rotor blockage and short circuits. The thermomagnetic tripping characteristic allows the current range to be precisely matched to the motor power within 11-16 A, providing selective protection and reducing the disconnection time in the event of a short circuit. The device performs switching (manual switching on/off of the motor) and protection (overload and short-circuit) functions, which allows it to be used as a motor starter in simple apLictions of control. The apparatus can be used in drive systems of machines, fans, pumps, conveyors and other equipment operating in industry, construction and technical infrastructure.
Assembly, compatibility and extensions
The compact design of PKZM0-16 allows quick installation on a standard DIN rail in switchboards and control cabinets. The apparatus is compatible with a wide range of Eaton accessories, such as auxiliary contacts, undervoltage and surge triggers, surface-mount enclosures, and adapters for busbar systems. Thanks to the PKZM0 series' unified dimensional concept, it is possible to create extensive starting systems in combination with contactors and control elements, while maintaining mounting consistency and ease of retrofitting. Clear operating elements and status indicators on the front of the device facilitate expLoatation and diagnostics under industrial conditions.
| Parameter | Value |
|---|---|
| Product type | Motor circuit breaker |
| Series | PKZM0 |
| Catalog number | 184762 |
| Type designation | PKZM0-16 |
| Number of poles | 3 |
| Current setting range | 11-16 A |
| Protection function | Thermomagnetic motor protection (overload and short-circuit) |
| Purpose | Protection and control of three-phase motors |
| Method of operation | Manual switching on and off with the knob on the front |
| Type of network | Three-phase AC |
| Design | Compact modular housing |
| Expandable | Contactors, auxiliary contacts, triggers, enclosures, Eaton system adapters |
| Mounting type | On a DIN rail in a switchboard or control cabinet |
| Typical applications | Machine drives, fans, pumps, conveyors, industrial and building installations |
| Manufacturer | Eaton |
The Eaton PKZM0-16 184762 motor circuit breaker combines reliable motor protection with simple operation and flexible mounting options. With its proven design, the PKZM0 series is a robust component of drive systems in apLication of industrial and building installations.
FAQ (customer)
- Q: What motor power range can this PKZM0-16 be used for?
A: It is designed for motors whose rated current falls within 11–16 A; the exact kW value depends on the suppLy voltage and motor efficiency. - Q: Can I use this device as a simpLe ON/OFF switch for the motor?
A: Yes, it can be used for manual switching of the motor in addition to providing overload and short-circuit protection. - Q: Is it suitable for DIN-rail mounting in a standard distribution board?
A: Yes, the PKZM0-16 is designed for quick mounting on a standard DIN rail. - Q: Do I need additional fuses with this motor-protective circuit breaker?
A: In many appLications it can be used without separate fuses, but final coordination must follow local standards and system design requirements. - Q: Can it be combined with a contactor for remote control?
A: Yes, it can be combined with Eaton contactors to form motor starters with remote control capability. - Q: Is there an indication when the device trips due to a fault?
A: The front operator shows the tripped position, allowing quick identification of a fault condition.
FAQ (expert)
- Q: What is the tripping class of the thermal release for PKZM0-16?
A: The device uses a standard thermal characteristic suitable for general-purpose motor protection; consult the series documentation for detailed time-current curves. - Q: How should I coordinate this breaker with upstream protection devices?
A: Select upstream breakers or fuses according to the maximum prospective short-circuit current and use Eaton coordination tables to ensure selectivity and back-up protection. - Q: Can PKZM0-16 be used in combination with soft starters or frequency inverters?
A: It can be used for line protection, but motor protection may need to be provided by the drive; follow the drive manufacturer’s recommendations. - Q: Are auxiliary contacts for signaling trip and ON/OFF status available?
A: Yes, clip-on auxiliary contact modules are available for status and fault indication. - Q: How should the current setting be adjusted in relation to the motor namepLate?
A: Set the dial to the motor’s rated current from the namepLate within the 11–16 A range to ensure correct thermal protection. - Q: Is type-2 coordination achievable with standard Eaton contactors?
A: Yes, type-2 coordination is possible when following Eaton’s coordination tables for PKZM0 with the respective contactor types.
Reviews
- Reliable motor protection device that has been working in our pump station for years without any issues.
- Compact size and easy DIN-rail mounting make panel assembly very straightforward.
- Clear adjustment scale for current setting helps match the breaker quickly to each motor.
- Robust construction suitable for industrial environments with frequent switching operations.
- Good compatibility with Eaton contactors and accessories simpLifies system standardization.
- Trip indication on the front makes troubleshooting much faster for maintenance staff.
- Works well as a combined starter and protection for small conveyor drives.
- Price-to-performance ratio is very good compared to separate fuse and switch solutions.
- We appreciate the modular accessories for remote indication and interlocking.
- Has provided stable operation in our HVAC distribution boards with minimal maintenance.