Alarm system partition keypad SATEL INT-S-W wall panel LED signaling 12 V DC
- INT-S-W partition keypad for operating a single partition of the INTEGRA alarm system, with white backlighting of keys and 2 A / 24 V DC relay for controlling the electric door strike or electromagnetic interlocking
Subscription products in your shopping cart
Set one delivery frequency for all subscription products in your cart every:
Subscription products in your shopping cart
INT-S-W - partition keypad with white backlighting for INTEGRA control panels
INT-S-W is a partition keypad designed for simple operation of a single partition of an alarm system based on the INTEGRA family of control panels. The device features white backlit keys and built-in access control and zone status indication functions.
- Operation of a single partition of the INTEGRA alarm system
- White backlighting of the keypad
- Panic, FIRE and AID alarms called from the keypad
- LEDs showing the partition status
- Audible signaling of selected system events
INT-S-W keypad purpose and applications
The INT-S-W partition keypad is designed to operate a single partition of an alarm system based on the INTEGRA family control panel, especially where partitions function as separate subsystems. With this solution, it is possible to conveniently control a single partition locally, without the need to provide the user with a full system keypad.
The device will find application, among others, in separated zones such as offices, warehouses, technical rooms or tenant zones, where simple local arming and disarming of the system and basic signaling of events are required.
Signaling and access control functions
INT-S-W offers extensive optical and acoustic signaling of zone states. LEDs indicate the status of the zone, and audible signaling conveys selected system events, making it easy for the user to assess the status of protection on an ongoing basis. Panic, FIRE and HELP alarms can be called directly from the keypad, enhancing user security.
Built-in access control functions include a relay designed to control an electric strike, bolt or electromagnetic interlock, and an input for door status monitoring. This allows the implementation of a simple access control system associated with an alarm zone using a single device.
Technical specifications
| Parameter | Value |
|---|---|
| Model | INT-S-W |
| Intended use | Simple operation of a single zone of an alarm system based on the INTEGRA family control panel |
| Alarm functions | Panic, FIRE, AID alarms called from keypad |
| Optical signaling | LEDs showing zone status |
| Acoustic signaling | Audible signaling of selected events in the system |
| Keypad backlighting | White backlighting of keys |
| Access control functions | Relay for control of electric door strike, bolt or electromagnetic interlock; input for door status monitoring |
| Environmental class | II |
| Power supply voltage | 12 V DC (±15%) |
| Operating temperature range | -10...+55 °C |
| Standby current consumption | 40 mA |
| Maximum current consumption | 75 mA |
| Maximum humidity | 93 ± 3% |
| Weight | 110 g |
| Dimensions | 80 × 127 × 24 mm |
| Relay output load capacity (resistive load) | 2 A / 24 V DC |
Technical data source:data sheet of INT-S-W model Link
FAQ - the most common questions about INT-S-W
1. What alarm control panels is the INT-S-W keypad designed for?
INT-S-W is designed for alarm systems based on the INTEGRA family of control panels.
2. How many partitions can the INT-S-W keypad support?
The INT-S-W keypad is designed for simple operation of a single zone of an alarm system.
3. What color is the INT-S-W model's key backlighting?
The INT-S-W model has white key backlighting.
4. What alarms can be triggered directly from the keypad?
The INT-S-W keypad can be used to call the PANIC, FIRE and HELP alarms.
5. Does the keypad indicate the status of the zone?
Yes, the LEDs on the keypad show the status of the zone.
6. Does the INT-S-W have audible signaling?
Yes, the keypad performs audible signaling of selected system events.
7. Can the INT-S-W control a door strike?
Yes, the built-in relay allows you to control the electric door strike, bolt or electromagnetic interlock.
8. Can the keypad control the status of the door?
Yes, the device has an input for door status monitoring.
9. In what temperature range can INT-S-W operate?
The temperature range of the keypad is -10 to +55 °C.
10. What is the power supply voltage of the keypad?
INT-S-W is powered by 12 V DC with a tolerance of ±15%.
11. What is the standby current consumption?
The standby current consumption is 40 mA.
12. What is the maximum current consumption of the keypad?
The maximum current consumption of the INT-S-W keypad is 75 mA.
13. What are the dimensions of the INT-S-W keypad?
The dimensions of the device are 80 × 127 × 24 mm.
14. What is the environmental class of the device?
The INT-S-W keypad belongs to environmental class II.
15. What is the maximum operating humidity of the keypad?
The maximum operating humidity is 93 ± 3%.
16. What is the maximum load of the relay output?
The load capacity of the relay output with resistive load is 2 A at 24 V DC.
17. How much does the INT-S-W keypad weigh?
The weight of the keypad is 110 g.
18. For which applications is the INT-S-W best suited?
The INT-S-W is best suited for applications where individual zones function as separate subsystems requiring local operation.
INT-S-W is a partition keypad dedicated to local operation of a single partition of an alarm system based on INTEGRA control panels. The device combines the functions of partition control, event signaling and basic access control in a compact housing.