VERSA PLus LTE control panel for small and medium-sized facilities
The VERSA PLus LTE control panel has been designed for the protection of small and medium-sized facilities, enabling the implementation of wired or wireless alarm systems. The device integrates several communication modules in a single motherboard, providing multi-channel transmission of event information.
- EN 50131 Grade 2 compliant.
- Supports wired and wireless alarm installations with ABAX 2, ABAX and MICRA controllers.
- Built-in communication modules: Ethernet, GSM/LTE, PSTN telephone dialer.
- Voice and acoustic alarm verification capability.
- Up to 30 programmable inputs and 12 programmable outputs.
- Support for up to 30 users with individual settings.
Characteristics and communication capabilities of the control panel
VERSA PLus LTE allows you to build an alarm system with a division into 2 zones and a maximum of 30 programmable zones and 12 programmable outputs, of which there are 4 wired inputs and 5 wired outputs on the main board. The control panel works with NO and NC type detectors, roller shutter and shock detectors, supports EOL and 2EOL configurations and has an additional NC type tamper input. Built-in Ethernet, cellular GSM/LTE and PSTN dialer modules allow monitoring to the station, voice, SMS and e-mail notification, remote programming and system control, with LTE/HSPA+/EDGE/GPRS data transmission depending on the capabilities of the cellular network used.
System control and utility functions
The system based on VERSA PLus LTE can be controlled using VERSA-LCD and VERSA-LCDM mechanical keypad LCD keypads, VERSA-KWRL2 wireless LCD keypads with built-in proximity card reader, INT-TSH210, INT-TSH2-R and INT-TSG2-R touchscreen keypads, INT-CR partition control module, remote controls, apLikation of VERSA CONTROL mobile and telephone (SMS, voice menu). The control panel offers memory for up to 2047 events, support for up to 30 users with unique codes, proximity cards and assigned keyfobs, and 4 timers for automatic arming and disarming of partitions and control of devices connected to the control panel outputs, such as lighting or sprinklers.
Service functions and hardware design
The VERSA PLus LTE motherboard is equipped with a built-in USB MINI-B socket for programming the control panel and updating firmware from a computer, and allows local or remote firmware updates using UpServ. The control panel's power supply provides an output voltage of 12 V DC ±15% and an output current of 2 A, a battery charging current of 800 mA, and power outputs AUX, KPD and +VR with specific current parameters. The design of the device is completed with a plug-in terminal strip, an output for connecting an enclosure-mounted piezoelectric transducer, and a 266 x 286 x 100 mm enclosure with a 173 x 105 mm electronics board.
Technical data
| Degree of protection according to EN 50131 | Grade 2 |
| Environmental class according to EN50130-5 | II |
| Supply voltage (±15%) | 18 V AC, 50-60 Hz |
| Power supply output voltage | 12 V DC ±15% |
| Output current of the power supply unit | 2 A |
| Battery charging current | 800 mA |
| Standby current consumption | 150 mA |
| Maximum current consumption | 300 mA |
| Standby current consumption from battery | 130 mA |
| Maximum current consumption from battery | 430 mA |
| Battery fault notification voltage (±10%) | 11 V |
| Battery cut-off voltage (±10%) | 10,5 V |
| Output voltage range | 10.5 V...14 V DC |
| High-current programmable outputs | 1100 mA / 12 V dc |
| Low-current programmable outputs | 50 mA / 12 V DC |
| Programmable relay output | 1000 mA / 30 V DC |
| AUX output | 500 mA / 12 V DC |
| KPD output | 500 mA / 12 V DC |
| +VR output | 200 mA / 12 V DC |
| Power supply outputs | 3 |
| Programmable wire inputs | 4 |
| Maximum number of programmable inputs | 30 |
| Programmable hard-wired outputs | 5 |
| Maximum number of programmable outputs | 12 |
| Zones | 2 |
| Timers | 4 |
| Communication buses | 1 |
| Manipulators | up to 6 |
| Users | 30 |
| Event memory | 2047 |
| Telephone numbers for notification | 8 |
| E-mail addresses for notification | 8 |
| Text messages | 64 |
| Voice messages | 16 |
| Maximum humidity | 93±3% |
| Operating temperature range | -10...+55°C |
| Housing dimensions | 266 x 286 x 100 mm |
| Electronics board dimensions | 173 x 105 mm |
| Recommended transformer | 40 VA |
Source of technical data:manufacturer's documentation SATELdatasheet of VERSA model PLus LTE Dokumentacja producenta
FAQ - frequently asked questions
- How many zones does the VERSA PLus LTE control panel support?
The VERSA PLus LTE control panel supports 2 zones. - How many maximum programmable zones can be configured in a VERSA PLus LTE system?
A maximum of 30 programmable zones can be configured in the system. - How many programmable wired outputs are available on the VERSA PLus LTE main board?
There are 5 programmable wired outputs available on the main board, including 2 high-current outputs, 2 low-current OC type outputs and 1 relay output. - What is the maximum number of programmable outputs in the VERSA PLus LTE system?
The maximum number of programmable outputs in the system is 12. - What types of detectors can be supported by VERSA PLus LTE zones?
The inputs support NO and NC type detectors, as well as roller shutter and shock detectors, with EOL and 2EOL configurations. - What built-in communication modules does VERSA PLus LTE have?
The control panel has built-in modules: Ethernet, GSM/LTE cellular, PSTN telephone dialer, voice module and acoustic alarm verification module. - What are the possibilities of communicating with the control panel using cellular technology?
The GSM/LTE module allows monitoring to the station, voice and SMS notification, remote control via voice menu, operation of apLication mobile and remote programming, with transmission parameters depending on the capabilities of the cellular network used. - How can a system based on VERSA PLus LTE be controlled?
Control is possible using VERSA-LCD and VERSA-LCDM LCD keypads, VERSA-KWRL2 wireless keypads, INT-TSH210, INT-TSH2-R and INT-TSG2-R touch-screen keypads, INT-CR module, remote controls, apLikation VERSA CONTROL and telephone (SMS, voice menu). - How many users can the VERSA PLus LTE control panel support?
The control panel supports up to 30 users. - What data can be recorded in the control panel's event memory?
The control panel's event memory can record up to 2047 events. - How many timers are available in the VERSA PLus LTE system and what are they used for?
There are 4 timers available in the system for automatic arming and disarming of partitions and controlling devices connected to the control panel outputs. - How many phone numbers and email addresses can be configured for notification?
You can configure 8 phone numbers for notification and 8 e-mail addresses. - How many text and voice messages does the control panel support?
The PBX supports 64 text messages and 16 voice messages. - What are the power supply requirements for the VERSA PLus LTE control panel?
The control panel requires a power supply voltage of 18 V AC (±15%), 50-60 Hz and is equipped with a power supply with an output voltage of 12 V DC ±15% and a current of 2 A. - What is the recommended power of the transformer to power the control panel?
The recommended transformer has a power of 40 VA. - In what temperature range can the VERSA PLus LTE control panel operate?
The control panel can operate in the temperature range from -10 to +55°C. - What is the permissible maximum operating humidity of the device?
The maximum operating humidity is 93±3%. - What are the dimensions of the VERSA PLus LTE housing and electronics board?
The dimensions of the housing are 266 x 286 x 100 mm, and the dimensions of the electronics board are 173 x 105 mm. - How many keypads can be connected to the control panel?
Up to 6 keypads can be connected to the control panel.
The VERSA PLus LTE control panel is designed for the implementation of alarm systems in small and medium-sized facilities, offering extensive communication and control of security zones. The integration of communication modules, alarm verification functions and flexible configuration of inputs, outputs and users allow the system to be adapted to the requirements of the installation according to the manufacturer's documentation.