Free delivery from 23,53 €
Heat Pump Monoblock Haier Super Aqua 7.8 kW AU082FYCRA(HW) + YR-E27 + ATW-A01 Set
Heat Pump Monoblock Haier Super Aqua 7.8 kW AU082FYCRA(HW) + YR-E27 + ATW-A01 Set
Heat Pump Monoblock Haier Super Aqua 7.8 kW AU082FYCRA(HW) + YR-E27 + ATW-A01 Set
Heat Pump Monoblock Haier Super Aqua 7.8 kW AU082FYCRA(HW) + YR-E27 + ATW-A01 Set
Heat Pump Monoblock Haier Super Aqua 7.8 kW AU082FYCRA(HW) + YR-E27 + ATW-A01 Set
Heat Pump Monoblock Haier Super Aqua 7.8 kW AU082FYCRA(HW) + YR-E27 + ATW-A01 Set
Our bestseller

Heat Pump Monoblock Haier Super Aqua 7.8 kW AU082FYCRA(HW) + YR-E27 + ATW-A01 Set

  • European Distribution Package: Haier Super Aqua Monoblock Heat Pump 7.8 kW AU082FYCRA(HW) with YR-E27 Wired Controller and ATW-A01 DHW Module Included
Size
2 003,53 €
incl. VAT / pcs.
Lowest price in 30 days before discount: / pcs.
Regular price: / pcs.
You can also buy using:
30 days for easy returns
This store offers an additional guarantee of up to €20,000 and Trusted Shops insurance. You receive the purchased item or a refund.
Brand
Symbol
AU082FYCRA(HW)
Producer code
9145455097661
Energy class
A+++

 

Haier Monoblock Air Source Heat Pump for Central Heating (CO) and Domestic Hot Water (DHW)
   
   The SUPER AQUA Monoblock heat pumps allow configuration with various heat emitters. The heat pump system offers a wide range of domestic hot water temperatures and the option to select or combine different heat emitters.
   
 Radiators

Heat pumps can deliver warmth through traditional radiators, which is especially important when upgrading the heating system in an existing building where radiators are already in place.
 Underfloor Heating

The SUPER AQUA heat pumps work exceptionally well with underfloor heating, ensuring high efficiency and lower energy bills.
Fan Coil Units

Another possible heat emitter is the fan coil unit, which is an ideal solution for both heating and cooling a building. 
     
   
 Easy Installation and Maintenance

Monoblock heat pumps are easier to install as they consist of only one outdoor unit and a controller that can be placed anywhere inside the building. Installing split heat pumps requires creating an additional connection—a refrigeration circuit. In the case of monoblock pumps, this complete system is housed within the unit, so the installation only requires connecting to the central heating system. This means they can be installed without an F-gas certification. The new Haier heat pump operates using the eco-friendly R32 refrigerant, which enhances the efficiency of the device.  
   
 

Reliable Operation in All Conditions

An intelligent sensor prevents the system from freezing in challenging conditions. When the ambient temperature drops below 3°C, the heat pump automatically starts working to avoid system damage. The flow switch monitors and signals when there is minimal water flow, helping to prevent water from freezing in the system during cooling mode.

 Convenient Control

The clear and intuitive wired controllers provided with the heat pumps allow you to select operating modes, set work schedules, and display error history, ensuring easy and efficient management of the system.
 

Very Quiet Operation at 59 dB(A)

The SUPER AQUA Monoblock heat pumps offer extremely quiet operation. The compressors in these units are covered with a special noise-insulating material, and a quiet DC fan motor is used along with an optimized fan shape that reduces vibrations.

 

 
 

Technical Data - Haier AU082FYCRA(HW) Heat Pump:

  • Seasonal Energy Efficiency Class for Space Heating (Moderate Climate):

    • LWT = 35°C: A++
    • LWT = 55°C: A+
  • Nominal Heating Capacity, Including Nominal Heating Capacity of All Additional Heaters (Moderate Climate, +7°C):

    • LWT = 35°C: 8 kW
    • LWT = 55°C: 7 kW
  • Seasonal Energy Efficiency for Space Heating (Moderate Climate):

    • LWT = 35°C: 151%
    • LWT = 55°C: 114%
  • Sound Power Level: 61 dB

  • Nominal Heating Capacity, Including Nominal Heating Capacity of All Additional Heaters (Cold Climate):

    • LWT = 35°C: 5 kW
    • LWT = 55°C: 4 kW
  • Nominal Heating Capacity, Including Nominal Heating Capacity of All Additional Heaters (Warm Climate):

    • LWT = 35°C: 9 kW
    • LWT = 55°C: 8 kW
  • Seasonal Energy Efficiency for Space Heating (Cold Climate):

    • LWT = 35°C: 116%
    • LWT = 55°C: 89%
  • Seasonal Energy Efficiency for Space Heating (Warm Climate):

    • LWT = 35°C: 164%
    • LWT = 55°C: 104%
  • Power Supply: 220-240/1/50-60

  • Heating (LWT = 35°C, External Temp: 2°C, 85% RH, EWT 30°C, LWT 35°C):

    • Output: 5.63 kW
    • COP: 3.23
  • Heating (LWT = 35°C, External Temp: 7°C, 85% RH, EWT 30°C, LWT 35°C):

    • Output: 7.01 kW
    • Power Consumption: 2.76 kW
    • COP: 2.54
  • Heating (LWT = 55°C, External Temp: 7°C, 85% RH, EWT 47°C, LWT 55°C):

    • Output: 7.8 kW
    • Power Consumption: 1.77 kW
    • COP: 4.4
  • Cooling (LWT = 18°C, External Temp: 35°C, EWT 23°C, LWT 18°C):

    • Output: 7 kW
    • Power Consumption: 2.06 kW
    • COP: 3.4
  • Cooling (LWT = 7°C, External Temp: 35°C, EWT 12°C, LWT 7°C):

    • Output: 5.5 kW
    • Power Consumption: 2.34 kW
    • EER: 2.35
  • Overcurrent Protection: C25

  • Power Supply (Cable Size): 3 x 2.5 mm²

  • Dimensions (WxHxD) Net/Gross: 950 x 965 x 395 / 1010 x 990 x 458 mm

  • Weight Net/Gross: 87/90 kg

  • Compressor Type: DC Inverter (Rotary)

  • Sensors:

    • Return Temperature Sensor
    • DHW Temperature Sensor (built-in ATW-A01 module)
  • Integrated Electric Heater: -

  • Refrigerant Type/Quantity: R32/1.5 kg

  • Expansion Valve: Electronic

  • Recommended Operating Range:

    • Cooling: 10-46°C
    • Heating: -20-35°C
    • DHW: -25-55°C
  • Water-side Heat Exchanger Type: Concentric Heat Exchanger

  • Water-side Connection Type: 1-inch

  • Water Pump Max. Head: 8 m

  • Warranty: 3 years* / 5 years* (with installation by an Authorized Service)
  • *Conditions apply as per the warranty card, and activation by an Authorized Service Center is required - a paid service
  • Water Outlet Temperature Range:

    • Cooling: 20-55°C
    • Heating: 5-20°C

1 Heating: Water inlet/outlet 40/45°C, ambient temperature 7/6°CDB.

2 Heating: Water inlet/outlet 30/35°C, ambient temperature 7/6°CDB.

3 Cooling: Water inlet/outlet 23/18°C, ambient temperature 35°CDB.

4 Cooling: Water inlet/outlet 12/7°C, ambient temperature 35°CDB.

All parameters are tested in a semi-anechoic chamber. The above data may be subject to updates. DHW only available with ATW-A01.

 
 
 
 
 
 
 

 

 