- Eaton CFEAPULLKIT accessory kit for pull-wire emergency stop switches. Enables construction of an E-STOP system along conveyor belts and conveyor lines in industrial environments.
Subscription products in your shopping cart
Set one delivery frequency for all subscription products in your cart every:
Subscription products in your shopping cart
Eaton Crouse-Hinds CFEAPULLKIT - Pull Wire Kit for Crouse-Hinds series emergency circuit breakers
The Eaton Crouse-Hinds CFEAPULLKIT is a compLet of accessories for creating a pull wire emergency stop system for industrial applications in demanding environments. The kit makes it possible to quickly and safely build a pull-wire emergency stop system on long stretches of conveyors, conveyor lines and machinery.
- CompLetable kit of components for the installation of CFEA series pull-wire emergency stop switches.
- Designed for demanding industrial and heavy-duty environments.
- Facilitates quick installation and service of safety systems on production lines.
- Dedicated for use with Eaton Crouse-Hinds Pullcord / Pull Wire safety switches.
- Provides uniform, factory-matched components to reduce the risk of assembly errors.
Use in machine safety systems
The Eaton Crouse-Hinds CFEAPULLKIT is designed specifically for the construction of pull-wire emergency stop systems along conveyor belts, feeders and other machines of considerable length. This solution allows operators to trigger the E-STOP function anywhere along the section to be protected, increasing the level of occupational safety and reducing response time in emergency situations.
The components included in the kit are compatible with Eaton Crouse-Hinds' Pull Wire / Pullcord series emergency stop switches and allow the wire to be routed, tensioned and firmly attached according to the manufacturer's requirements. The kit is dedicated to industrial environments where high reliability and mechanical resistance are required.
Benefits of using the CFEAPULLKIT kit
Choosing the Eaton Crouse-Hinds CFEAPULLKIT factory kit simplifies the design and installation process of a safety system, eliminating the need to select individual components from different sources. The user receives a structurally consistent solution that follows the switch manufacturer's guidelines, minimizing the risk of improper installation and ekspLoatation problems.
The use of industrial-quality components results in stable wire guidance, repeatable tension and reliable interaction with the switch mechanism. This translates into both operator safety and a reduction in nonpLance downtime associated with faulty operation of the emergency system.
| Comparative parameter | Description |
|---|---|
| Purpose | CompLet accessories for Eaton Crouse-Hinds pull-wire emergency circuit breakers |
| Type apLication | E-STOP systems with pull cord along conveyors and process lines |
| Parameter | Value |
|---|---|
| Product name | Eaton Crouse-Hinds CFEAPULLKIT - Pull Wire Kit for Crouse-Hinds series emergency stop switches |
| Product type | Accessory kit for emergency pull wire circuit breakers (pull wire kit) |
| Series / family | Eaton Crouse-Hinds - Pull Wire / Pullcord emergency circuit breaker systems |
| Application | Emergency stop systems (E-STOP) on conveyor belts, conveyor lines and other long machines |
| Compatibility | Eaton Crouse-Hinds emergency pull-wire switches (Pull Wire / Pullcord) of the corresponding series |
| Operating environment | Industry, apLications requiring high reliability and mechanical durability |
| Safety function | Allowing the emergency stop function to be tripped anywhere along the protected section |
| Type of operation | Mechanical tripping of the switch by pulling the cable tightened on special guide and fastening elements (included in the set) |
| Mounting method | Installation along the conveyor or process line, according to the switch manufacturer's guidelines and safety system configuration |
| Components included | CompLet industrial components necessary for the installation of the pull cord to the emergency switch (detailed composition according to the manufacturer's documentation for the CFEAPULLKIT model) |
| Intended use | To ensure simple installation, proper pull cord tension and reliable operation with the emergency stop mechanism |
| Target industries | Manufacturing, mining, materials handling, material handling, internal transportation, other apLications with long conveyors and belt systems |
| Maintenance | Periodic inspection of the cable tension, the mechanical condition of the guiding and fixing elements, and the correct operation of the emergency stop, according to the manufacturer's recommendations |
| Manufacturer | Eaton |
| Brand | Eaton Crouse-Hinds |
| Model / part number | CFEAPULLKIT |
The Eaton Crouse-Hinds CFEAPULLKIT kit provides a practical and consistent solution for building a pull-wire emergency circuit breaker system in apLication of industrial facilities. With pre-selected components, it simplifies installation, increases reliability and supports the maintenance of a high level of safety at workplaces.
FAQ (customer)
- What is the Eaton Crouse-Hinds CFEAPULLKIT used for? It is a pull wire accessory kit designed to build or extend emergency stop cable systems for Eaton Crouse-Hinds pull wire emergency stop switches.
- Can I use this kit with any brand of pull wire switch? It is specifically optimized for Eaton Crouse-Hinds pull wire emergency stop devices, and compatibility with other brands is not guaranteed.
- Is the pull wire kit suitable for long conveyor lines? Yes, it is intended for use along extended conveyor systems and material handling lines where operators must access an E‑stop function at many points.
- Does the kit include the emergency stop switch itself? No, the emergency stop switch must be ordered separately; the kit provides the mechanical accessories for the pull wire installation.
- Can I install the kit myself? Installation should be carried out by qualified personnel familiar with machine safety standards and the specific Eaton Crouse-Hinds emergency stop device.
FAQ (expert)
- Is CFEAPULLKIT intended for hazardous (Ex) locations? The kit is engineered for use with Crouse-Hinds equipment; appLicability in hazardous areas depends on the associated switch certification and system design.
- Does the kit define a maximum cable length? The maximum permissible cable length is determined by the associated Eaton Crouse-Hinds pull wire switch and must follow the limits given in the switch datasheet and manual.
- How should tensioning be verified during commissioning? Tension must be adjusted in accordance with the pull wire switch installation instructions, with functional checks along the entire length to confirm reliable tripping and reset.
- Can the kit components be mixed with third‑party hardware? For predictable performance and to maintain manufacturer responsibility, only components approved by Eaton should be used.
- What maintenance regime is recommended? Regular inspection intervals should include checking wire tension, mechanical wear of pulleys and anchors, and functional tests of the compLete emergency stop circuit.
Reviews
- Reliable pull wire kit that integrates well with our existing Crouse-Hinds emergency stop switches.
- The factory-selected components made design and installation of the conveyor E‑stop line straightforward.
- Durable hardware that has held up well in a demanding industrial environment.
- Clear separation between the switch and the accessory kit allowed us to configure the system flexibly.
- After commissioning, the operators appreciated having continuous access to an emergency stop along the entire conveyor.
- Routine inspections showed minimal wear and stable cable tension over time.
- Good choice when standardizing on Eaton Crouse-Hinds safety solutions across multipLe pLants.
- The kit helped reduce engineering time compared with sourcing miscellaneous components separately.
- We experienced consistent tripping behavior along the full cable length after correct tensioning.
- Overall, a practical and robust accessory set for pull wire emergency stop appLications.