Wilo-Stratos MAXO Premium Smart Pump
Top efficiency Inline glandless pump with EC motor and electronic capacity adjustment. Use for hot water, cold water and a mixture of water and glycol. Energy efficiency index (EEI) depending on pump type ≤ 0.17 and ≤ 0.19.
Types of regulation:
- Constant, automatic adaptation of power to the requirements of the installation without entering setpoints Wilo-Dynamic Adapt plus (factory setting). Energy consumption savings of up to 20% compared to dp-v control mode.
- Fixed temperature (T-const.)
- Constant differential temperature (dT-const.)
- Demand-driven optimization of feed pump rotational flow by connecting and communicating with several pumps (Multi-Flow Adaptation).
- Constant flow (Q-const.)
- Adjustment of the differential pressure dp-c at a remote point in the pipeline (erroneous point control)
- Constant differential pressure (dp-c)
- Variable differential pressure (dp-v) with nominal operating point input option
- Constant speed (n-const.)
- User-defined PID control
Features:
- Registration of heat quantity
- Registration of cold quantity
- Automatic shutdown when zero flow is detected in the pump (No-Flow Stop)
- Switching between heating and cooling modes (automatic, external and manual)
- Adjustable flow limitation by Q-Limit function (Qmin. and Qmax.)
- Type of dual pump operation: Efficiency-optimized operation with attachment for dp-c and dp-v, primary operation mode / reserve operation mode
- Save and restore configured pump settings (3 points to restore settings)
- Failure / warning signaling in text form with help
- Venting function for automatic venting of the rotor chamber
- Automatic operation in night-time lowering mode
- Automatic non-locking functions and built-in full motor protection
- Dry run detection
Indication:
- Type of adjustment
- Setpoint
- Flow
- Temperature
- Power consumption
- Power consumption
- Factors that have an active impact (e.g., STOP, No-Flow Stop)
Version:
- 2 configurable analog inputs: 0 - 10 V, 2 - 10 V, 0 - 20 mA, 4 - 20 mA and standard PT1000; power supply from +24 V DC
- 2 configurable digital inputs
- 2 configurable relays for operation messages and fault indication
- Wilo CIF module socket with interfaces for building automation
- Wilo Net as Wilo bus system for product communication
- Integrated temperature sensors
- Automatic emergency mode
- Graphic color display (4.3 inches)
Scope of delivery:
- Pump
- Optimized Wilo-Connector
- Gaskets, washers
- Thermal insulation covers
- Installation and operating instructions
Optional accessories:
- ClimaForm refrigeration insulation
- CIF module: Modbus TCP, Modbus RTU
- PT 1000 sensors